• Detection Range : 90°
    (1 CH / 4 CH)
  • 3D Flash Type
  • Equipped with The VCSEL
    (940 nm)
  • Applicable to the Platform Safety Doors(PSD)

Model

Model

External Dimension(mm)

External Dimension(mm)

General Spec.

General Spec.
Item Product Spec.
Size 120 x 109 x 47.5 mm (For both the 1 CH and 4 CH)
Sensing Type VCSEL, QVGA
Scanning Type 3D Flash
Power Supply DC 12 V ~ 36 V
Power
Consumption
12 W. Max.
Detection Laser Power 4 W
Laser Emission Angle 90°
IR Laser 940 nm
LED 650 nm, 3 mW
(According to The Installation Guides)
Scanning Range Up to 5.6 M
Scanning Angle Resolution 0.3°
Object Reflection Ration More than 5 %
(For a Distance of 3.5 M)
IP Grade IP 66
Setting Method Dedicated App
(WiFi Communications)

Environmental Spec.

Environmental Spec.
Insulation Resistance Test 500 V DC, More than 5 MΩ
(For 1 Min.)
IP Test IP 66
Withstand the Voltage Test AC 500 V, Less than 10 mA
(For 1 Min.)
Power Supply Fluctuation Test DC 24 V±20%
Electro Magnetic Compatibility(EMC) KS C IEC 62236-4
KS C IEC 61000-4-2~9
High-Temp.,
High-Humidity Test
-25 ℃, 95 % R.H. / 50 ℃, (90 ~ 96) %
Dwelling Time of 5 Hours for each
RH Segment, 2 Cycle
Temp. Cycle Test -40 ℃ / 70 ℃
A Dwelling Time of 30 Min.
for each Segment, 5 Cycle
Vibration Test 5-2000 Hz, 2.3 m/s2(rms)
30 Min. for each of the X, Y, Z Axis
High-Temp. Operational Test (70±3) ℃, 16 h Impact Test 20 g, 11 ms, Half Sine, 50 Times/Min.
Low-Temp. Operational Test (-40±3) ℃, 16 h
Insulation
Resistance Test
500 V DC, More than 5 MΩ
(For 1 Min.)
Withstand the Voltage Test AC 500 V, Less than 10 mA
(For 1 Min.)
Electro Magnetic Compatibility(EMC) KS C IEC 62236-4
KS C IEC 61000-4-2~9
Temp. Cycle Test -40 ℃ / 70 ℃
A Dwelling Time of 30 Min.
for each Segment, 5 Cycle
High-Temp. Operational Test (70±3) ℃, 16 h
Low-Temp. Operational Test (-40±3) ℃, 16 h
IP Test IP 66
Power Supply Fluctuation Test DC 24 V±20%
High-Temp.,
High-Humidity Test
-25 ℃, 95 % R.H. / 50 ℃, (90 ~ 96) %
Dwelling Time of 5 Hours for each
RH Segment, 2 Cycle
Vibration Test 5-2000 Hz, 2.3 m/s2(rms)
30 Min. for each
of the X, Y, Z Axis
Impact Test 20 g, 11 ms, Half Sine, 50 Times/Min.

Connector Spec.

Connector Spec.
No. Cable’s Color Signal Remarks
1 White 12 V ~ 36 V 0.5 A Power
Supply
2 Pink 12 V ~ 36 V 0.5 A
3 White(DOT) GND
4 Pink(DOT) GND
5 Orange DETECT Relay 1
6 Orange(DOT) GND
7 Yellow ERROR Relay 2
8 Yellow(DOT) GND

System Application

System Application

PRODUCT LIST

Kwangwo KakaoTalk inquiry To Top