• NC Tooling Machine
  • Aluminum Dial(Silver)
  • Industrial Application
  • Long Life
  • High Reliability
  • Customized Logo can be Available Half Permanent Durability

Model

Model

External Dimension(mm)

External Dimension(mm)

Output Circuit

Output Circuit

Open Collector

Voltage Output

Line Driver

Signal Spec.

Signal Spec.

Open Collector, Voltage Output

Line Driver

Electrical Spec.

Electrical Spec.
Output Type Open Collector Voltage Output Line Driver
Power Supply DC +5[V] ~ +15[V]Ripple p-p : Less than 5 % DC +5[V]Ripple p-p : Less than 5 %
Consuming Current (In case of No Load) 70 mA Max. 70 mA Max. 150 mA Max.
Maximum Frequency Response 5 KHz Max.
Output Voltage Less than VL 0.5[V] / More than VH 2.5[V]
Output Current Less than 20 mA
Rising, Falling Time Less than 3 μs Less than 0.1 μs
Common Conditions In case that the cable length of output side is 1[M] and load resistor is Less than 1[kΩ]

Mechanical Spec.

Mechanical Spec.
Starting Torque 300 gf – cm Max. Weight 185 g
Maximum Number of Revolution 600 rpm
Bearing Lifetime 50,000[hr]
(In case of Rotating by 3,000 rpm)
Connection Table 6 P
Starting Torque 300 gf – cm Max.
Maximum Number of Revolution 600 rpm
Bearing Lifetime 50,000[hr] (In case of Rotating by 3,000 rpm)
Connection Table 6 P
Weight 185 g

Environmental Spec.

Environmental Spec.
Operating Temp. Range -10 °C ~ +70 °C (No Freezing) Internal Vibration 5 G
Preserving Temp. -20 °C ~ +85 °C Internal Shock 50 G
Using Humidity 35 % ~ +80 % RH Ingress Protection IP 50
Preserving Humidity 30 % ~ +85 % RH
Operating Temp. Range -10 °C ~ +70 °C (No Freezing)
Preserving Temp. -20 °C ~ +85 °C
Using Humidity 35 % ~ +80 % RH
Preserving Humidity 30 % ~ +85 % RH
Internal Vibration 5 G
Internal Shock 50 G
Ingress Protection IP 50

Connector Spec.

Connector Spec.
Cable Configuration
Open Collector, Voltage Output, Line Driver
Cable Configuration - Open Collector, Voltage Output, Line Driver Connector Spec.

PRODUCT LIST

Kwangwo KakaoTalk inquiry To Top